This website is designed to work with recent browsers. With your current version, you may find it difficult to navigate. Click here to find and download a more recent browser.

BLUON TdX 20

Keep your current equipment in place and make it run longer and better than ever with Bluon TdX 20.

This isn’t just a replacement for R-22, it’s an actual upgrade.

Bluon TdX 20 Multiphase Approach

All HVAC-R equipment works by changing a liquid refrigerant to a gas and back again, absorbing and dispelling heat in the process. Only TdX 20 takes this liquid-to-gas phase change to a new level.

bullets-02
5 constituents phase change in a carefully orchestrated sequence
bullets-01
Heat is absorbed across more of the coil surface area, improving overall heat transfer
bullets-04
Compressor workload is reduced, resulting in less amp draw and lower compressor head temperature
bullets-03
Compressor stability is improved, resulting in less noise and vibration and more stable amp draw

So what does
that really mean?

baton

Visualize a 500-meter sprint, with one runner doing all the work, versus a 5 runner relay in which the work is divided and passed from one runner to the next, allowing each runner to carry more speed and take on less pressure.

 

 

WATCH THE VIDEO BELOW TO SEE THE COMPLETE PROCESS

 

TdX 20 Increases Compressor Stability

Same unit, same operating conditions, major performance difference:
TdX 20 reduces amp “creep” and stabilizes compressor utilization.

compressor-stability-h
compressor-stability-v

TdX 20 PRODUCT COMPARISON CHART

Manufacturer SEVERAL OFF PATENT dupont icor tinyOtherCompany
Product R-22 TdX 20 R-407C M099 NU22 R-421A
ENERGY EFFICIENCY INCREASE/DECREASE Baseline +5 to +25% -5% to -10% -10% to -20% -10% to -20% -15% to -25%
CAPACITY Baseline Equal
(can be slightly
more or less)
Slight
Decrease
Slight
Decrease
Notable
Decrease
Notable
Decrease
VAPOR PRESSURE AT 100°F (psig) 195.9 164.7 196.1 187.3 182.9 181.0
LATENT HEAT OF VAPORIZATION (kj/kg) 234 239 244 211 192 188
LATENT HEAT EFFICIENCY (LHoV / pressure ) 1.19 1.45 1.24 1.13 1.05 1.04
MOLECULAR WEIGHT (g/mol) 86.5 89.9 86.2 99.1 108.5 111.7
MASS FLOW RATE (%) Baseline -1 -2 +12 +20 +21
GWP 1810 1650 1774 2265 2526 2631
OZONE DEPLETING POTENTIAL (ODP) Yes None None None None None
ASHRAE SAFETY RATING A1 A1 A1 A1 A1 A1
EQUIPMENT MODIFICATION Baseline None Oil change
required
None None None
OIL COMPATIBILITY MO, AB MO, POE, AB POE MO, POE, AB MO, POE AB MO, POE AB
WARRANTY No Yes No No No No

Download this chart (PDF)

The information provided herein is based on technical data that Bluon Energy believes to be reliable. Conditions of product use are outside our control; therefore we make no warranties, expressed or implied, and assume no liability in connection with any use of this information. Bluon Energy and Bluon TdX are trademarks of Bluon Energy LLC. All other trademarks are the property of their respective owners. All rights reserved. © 2016 Bluon Energy.

Why Choose Bluon TdX 20

© 2016 Bluon Energy LLC